When programming is underway, a further progress
report,
Programming block
n of 7 yy%
, is displayed.
When recovery is complete,
Recovery complete,
remove the diskette and return boot block switch
to the off position before rebooting
is displayed.
6. Remove the flash diskette from the diskette drive.
7. Turn the server off.
8. Remove the jumper on the boot-block jumper block or
move pins 2 and 3 to return to normal startup mode.
9. Restart the server. The system should start up
normally.
Troubleshooting the Ethernet controller
This section provides troubleshooting information for
problems that might occur with the 10/100 Mbps Ethernet
controller.
Network connection problems
If the Ethernet controller cannot connect to the network,
check the following:
v
Make sure that the cable is installed correctly.
The network cable must be securely attached at all
connections. If the cable is attached but the problem
persists, try a different cable.
If you set the Ethernet controller to operate at 100
Mbps, you must use Category 5 cabling.
If you directly connect two workstations (without a hub),
or if you are not using a hub with X ports, use a
crossover cable.
Note:
To determine whether a hub has an X port, check
the port label. If the label contains an
X
, the hub
has an X port.
v
Determine if the hub supports auto-negotiation. If not, try
configuring the integrated Ethernet controller manually to
match the speed and duplex mode of the hub.
v
Check the Ethernet controller lights on the operator
information panel.
These lights indicate whether a problem exists with the
connector, cable, or hub.
– The Ethernet Link Status light illuminates when the
Ethernet controller receives a LINK pulse from the
hub. If the light is off, there might be a bad connector
or cable, or a problem with the hub.
– The Ethernet Transmit/Receive Activity light
illuminates when the Ethernet controller sends or
receives data over the Ethernet Network. If the
Ethernet Transmit/Receive Activity light is off, make
24
: Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y,
41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Содержание Netfinity 5100 8658 21Y
Страница 1: ...Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY S10K 2615 00...
Страница 10: ...x Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 23: ...Watch for the System Power light on the operator information panel to stop blinking General information 13...
Страница 26: ...16 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 50: ...40 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 65: ...13 PCI slot 2 32 bit J32 Installing options 55...
Страница 195: ...Parts listing Type 8658 Copyright IBM Corp 2000 185...
Страница 196: ...186 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 215: ...Related service information 205...
Страница 216: ...206 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 217: ...Related service information 207...
Страница 218: ...208 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 219: ...Related service information 209...
Страница 220: ...210 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 221: ...Related service information 211...
Страница 222: ...212 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 235: ...Related service information 225...
Страница 236: ...226 Netfinity 5100 Type 8658 Models 11Y 21Y 31Y 41Y 51Y 1RY 2RY 3RY 4RY 5RY...
Страница 237: ...Related service information 227...
Страница 245: ......
Страница 246: ...Part Number 10K2615 Printed in U S A S10K 2615 00 1P P N 10K2615...