Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
69C7
Abnormal or unexpected HSL OptiConnect disconnection from a remote
system or partition.
The local system or partition disconnected from a remote system or
partition due to an unexpected event or failure. LIC will attempt to recover
from the error. Intervention at the local or remote system or partition may
be required.
Possible causes are: time out, hang or hardware failure. The problem may
be with: the local system or partition or the remote system or partition.
If there was not a complete HSL loop before this error then a failure or
power down in an HSL component between the local system or partition
and the remote system or partition could have caused this error. Check for
SRCs with FRUs like: HSL cables, HSL I/O bridge or a power problem in
an expansion I/O tower or unit on this loop.
Examine the SAL on the local system or partition for failures on the same
loop, or with the Network Interface Controller at approximately the same
time.
Examine the remote system or partition for problems. Correct any HSL or
NIC problems you find with the remote and local systems or partitions.
If there are no problems with the remote system or partition and there are
no problems with the local system or partition then collect all the PAL
information for this failure on both systems. Be sure to record all words in
the SRC. Contact your next level of support.
B6xx (including A6xx)
System Reference Codes