Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
2222
Power Good Type M Fault
A Memory power good fault occurred.
2223
Power Good Type P Fault
A Processor power good fault occurred.
2224
Power Good Type I Fault
A Internal expansion power good fault occurred.
2231
System Unit Interlock Failure
2232
Secondary Frame Interlock Failure
2240
Air Moving Device Panel Fault
2241
Air Moving Device 1 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
2242
Air Moving Device 2 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
2244
Air Moving Device 4 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
2245
Air Moving Device 5 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
2246
Air Moving Device 6 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
2260
Timeout on Panel for Request of VPD
2301
Power Supply P01 or P02 Overcurrent error
A POW-PIP is required for identifying which load is at fault.
2302
Power Supply P03 or P04 Overcurrent error
A POW-PIP is required for identifying which load is at fault.
2311
Power Supply P01 error
A fault detection failure occurred for Power Supply P01.
1xxx
94
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)