Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
903B
Invalid Packet Length for data sent.
The number of bytes sent or received does not match the number of bytes
specified in the command.
No action required. This reference code is logged for error analysis only.
9041
Invalid Load Type
The down load was successful, but the wrong type of Licensed Internal
Code was loaded. The operation was attempted again but was not
successful. Exchange the failing items for the node reporting the fault.
AJDG301
TWRCARD
9042
EEPROM Failure
The EEPROM in an SPCN node cannot be written successfully.
Exchange the SPCN node reported in the failure.
9043
Download Failure
The Licensed Internal Code download to an SPCN node was completed
but was not successful.
Exchange the failing SPCN node.
9046
QDS Packet Sequence Error
The Packet Sequence number is wrong. The download was stopped.
9047
QDS Block Sequence Error
The Block Sequence number is wrong. The download was stopped.
9048
The SPCN ROS and EEPROM LIC is not compatable.
The LIC levels in the nodes ROS and EEPROM are not compatible.
Exchange the failing items for the failing node.
TWRCARD
AJDG301
9080
Undefined Status Code
An SPCN node returned an unknown status code.
Exchange the failing SPCN node.
90F0
A frame was dropped from the SPCN configuration.
A frame was dropped from the SPCN configuration. This is usually caused
by a loss of ac power or a problem with the frame-to-frame cable.
90F1
A frame was added to the SPCN configuration.
No action required. This reference code is logged for information only.
9100
Battery capacity test completed.
No action required. This reference code is logged for information only.
9101
VLIC-SPCN Timeout
A Licensed Internal Code timeout occurred. The SPCN failed to respond to
a Licensed Internal Code command.
9102
Assign Permanent Address command failure
A node failed to perform an Assign Permanent Address command.
1xxx
System Reference Codes
113