Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0104
Device detected parity error from WS IOP
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
0105
WS IOP detected error when transmitting data
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
0106
WS IOP detected wrong data from device
Perform WSAC-PIP1.
FI00601
FI00631
GXC7777
FI00730
0107
WS IOP detected wrong address from device
Perform WSAC-PIP1.
0108
WS IOP detected device power turned off, and then on
Perform WSAC-PIP1.
GXCEEEE
FI00601
0109
WS IOP detected wrong device response to start command
Perform WSAC-PIP1.
0111
WS IOP detected wrong keyboard scan code from display
Perform WSAC-PIP1.
0120
Device detected wrong command or device ID from WS IOP
Perform WSAC-PIP1.
0121
Device detected not valid value from WS IOP
Perform WSAC-PIP1.
0122
Device detected storage or data overrun
Perform WSAC-PIP1.
0123
Device detected null or attribute exception error
Perform WSAC-PIP1.
0124
Device detected wrong start command from WS IOP
Perform WSAC-PIP1.
0125
WS IOP detected wrong exception response from device
Perform WSAC-PIP1.
0126
WS IOP detected not valid pass-through command
Perform WSAC-PIP1.
GXC9999
FI00730
0149
WS IOP detected wrong request or response from device
Perform WSAC-PIP1.
0190
WS IOP detected no status change from device
Perform WSAC-PIP1.
0191
WS IOP detected busy time-out from device
Perform WSAC-PIP1.
B075