Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
C62E
SPCN Network Fault
An SPCN frame-to-frame communication failure was detected.
C701 to C703
SPCN Frame-to-Frame Communication fault
CB00
Unknown box ID
The SPCN node cannot determine the machine type of the box in which it
is installed.
CB05 to CB06
AC Module Failure
The SPCN ROS and EPROMs test failed.
CB1D
AC Module Failure
The LCD test failure was detected on an Extension/Expansion Unit.
ACMODUL
17G0573
CC00
AC Module Failure
An unknown fault was detected. The machine failed to power up.
CD00
No Power Supplies Present
SPCN cannot detect any power supplies installed.
CE18
Regulator Not Present
No regulators can be found.
If the regulators are installed, exchange the failing items.
CE1A
Regulator Not Present
If regulator 3 in slot R03 is installed, exchange the failing items.
D001
A Battery Power Unit 1 Failed
A response was received from battery power unit 1 charger that was not
valid.
86G8020
ACMODUL
BACKPLN
D002
Battery Power Unit 2 Failed
A response was received from battery power unit 2 charger that was not
valid.
86G8020
ACMODUL
BACKPLN
D101
A Battery Power Unit 1 Failed
Battery power unit 1 capacity test failed.
86G8040
86G8020
D102
Battery Power Unit 2 Failed
Battery power unit 2 capacity test failed.
86G8040
86G8020
D110
Battery Power Unit 1 and 2 Failed
Replace both batteries.
D201
A Battery Power Unit 1 Failed
Battery power unit 1 charging fault was detected.
86G8020
86G8040
D202
Battery Power Unit 2 Failed
Battery power unit 2 charging fault was detected.
86G8020
86G8040
1xxx
54
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)