9 - DATA0019
Each reference code has an associated Failing Item, given in the table below. Here
the failing item is a Symbolic FRU. When you use the reference code and
description when following the procedure described in the Symbolic FRU
documentation, you should end up with a hardware FRU, code update, or
directions to call your next level of support.
Each reference code also has an associated Priority Code. The first digit of the
reference code in the table below gives the priority.
v
Mandatory
priority reference codes start with either a
4
,
5
, or
7
.
v
High
priority reference codes start with either a
8
,
9
, or
B
.
v
Low
priority reference codes start with either a
C
,
D
, or
F
.
You should replace all mandatory failing items before the next IPL. A FRU with a
high priority has a high probability of resolving the problem. Replace high priority
failing items in order, one at a time with an IPL in between. A FRU with a low
priority has a low probability of resolving the problem. Replace low priority failing
items after replacement of mandatory and high priority items.
For more on the Failing Item column entries, see Table 2. System Processor Failing
Items Details — Models 830 & SB2, which follows the reference code table below.
Table 1. (B437) System Processor Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
4001
System Card(s) or BackPlane
4003
System Card(s) or BackPlane
4004 to 4005
System Sub-Card(s)
4009
System Card(s) or BackPlane
40A0
Service processor Licensed Internal Code
AJDGP01
40A1
Licensed Internal Code error
AJDG301
40A2
Service processor Licensed Internal Code
AJDGP01
40A4
Call your next level of support for assistance
40A6
Main storage failure
40E1
Service processor Licensed Internal Code
AJDGP01
4200
System Card(s) or BackPlane
4201 to 4208, 420D
to 420F, 4211 to
4218, 421D to
421F, 4221 to 4228,
422D to 422F, 4231
to 4238, 423D to
423F
System Sub-Card(s)
42FF
System Sub-Card(s)
4300, 4400, 4500
System Card(s) or BackPlane
B437
250
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)