Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
BBBB
Battery not working correctly
A problem was detected with the battery supplying power to the
time-of-day clock. The battery is either weak or is not connected securely.
Note:
This is not a critical failure. However, if there is a power failure, the
time of day will be lost.
Table 2. (0000) Control Panel Reference Codes for system Models 830, 840, 870,
890, SB2, and SB3
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
1110 to 1113
Failure of CEC power supply not identified by SPCN.
This reference code can be caused by something holding the system Power
On Reset (POR) line active.
1114
Operators panel and service processor have been reset
This reference code can be caused by something holding the system Power
On Reset (POR) line active.
2222
Service processor failure caused machine check interrupt.
Before exchanging the TWRCARD, remove the adapter cards from the
TWRCARD and perform an IPL. If the IPL completes successfully, one of
the adapter cards you removed is defective.
3333
SPCN to CSP interface error.
An attempt to communicate between the SPCN and the CSP processor
failed.
3334
CSP to VPD Collector interface error.
An attempt to communicate between the CSP and the VPD Collector failed.
4444
Power on request failure
A power-on request was not completed successfully. A control
panel-detected power-on failure occurred.
5553
Incorrect key used or the key is not completely inserted
The key inserted is not the correct key or is not completely inserted.
AABB
Remote power-on failure
An attempt was made to power on the system by a remote power-on
operation with the keylock mode on the control panel set to Secure or
Manual. To correct the problem, select Normal or Auto mode on the control
panel and perform the remote power-on operation again, if necessary.
AACC
Service processor power-on failure
An attempt was made to power on the system from the service processor
with Secure or Manual mode selected on the control panel. To correct the
problem, select Normal or Auto mode on the control panel and perform
the service processor power-on operation again, if necessary.
Note:
This reference code may occur if the service processor card was
exchanged and Manual mode was selected. Select Normal mode on the
control panel.
0000
8