Beep
code
descriptions
If
POST
or
the
BMC
detects
a
problem
during
startup,
it
might
emit
one
or
more
beep.
You
can
use
the
following
beep
code
descriptions
to
help
diagnose
and
solve
problems
that
are
detected
during
startup.
Beep
codes
indicating
specific
system
problems
are
listed
in
the
following
tables.
See
“Diagnostics”
in
the
BladeCenter
HS40
Type
8839
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
on
the
IBM
BladeCenter
Documentation
CD
or
the
IBM
BladeCenter
T
Documentation
CD
that
comes
with
your
blade
server
for
more
information
about
the
beep
codes.
Table
3.
POST
beep
code
descriptions
Beep
code
Descriptions
of
the
POST
beep
codes
1,
2,
or
3
Memory
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
memory
modules
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
6
and
7
System
error.
Call
for
service.
5
short
and
1
long
Memory
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
memory
modules
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
6
short
and
1
long
Memory
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
memory
modules
are
of
the
correct
type
and
that
they
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
7
short
and
1
long
System
memory
error.
Call
for
service.
Table
4.
BMC
beep
code
descriptions
Beep
code
Descriptions
of
the
BMC
beep
codes
1-5-1-1
Microprocessor
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
microprocessors
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
1-5-2-2
No
microprocessor
detected.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
microprocessors
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
1-5-2-3
Microprocessor
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Make
sure
that
the
microprocessors
are
of
identical
type
and
that
they
are
installed
correctly.
2.
Turn
off
the
blade
server;
then,
restart
the
blade
server.
If
the
problem
remains,
call
for
service.
1-5-4-2
Power
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Remove
the
blade
server
from
the
BladeCenter
unit;
then,
reinstall
it
and
restart
the
blade
server.
2.
If
the
problem
remains,
call
for
service.
1-5-4-4
Power
error.
Complete
the
following
steps
if
this
problem
occurs:
1.
Remove
the
blade
server
from
the
BladeCenter
unit;
then,
reinstall
it
and
restart
the
blade
server.
2.
If
the
problem
remains,
call
for
service.
66
BladeCenter
HS40
Type
8839:
Installation
and
User’s
Guide
Содержание HS40 - BladeCenter - 8839
Страница 3: ...BladeCenter HS40 Type 8839 Installation and User s Guide ERserver...
Страница 8: ...vi BladeCenter HS40 Type 8839 Installation and User s Guide...
Страница 76: ...62 BladeCenter HS40 Type 8839 Installation and User s Guide...
Страница 90: ...76 BladeCenter HS40 Type 8839 Installation and User s Guide...
Страница 114: ...100 BladeCenter HS40 Type 8839 Installation and User s Guide...
Страница 118: ...104 BladeCenter HS40 Type 8839 Installation and User s Guide...
Страница 119: ......
Страница 120: ...Part Number 90P3102 Printed in USA 1P P N 90P3102...