2.
Grip
the
power-module
handle
with
one
hand
and
slowly
pull
the
power
module
out
of
the
bay.
Use
your
other
hand
to
support
the
bottom
of
the
power
module
as
you
pull
the
power
module
out
from
the
bay.
Attention:
Do
not
carry
the
power
module
by
only
the
power-module
handle.
You
must
support
the
weight
of
the
power
module.
3.
Place
the
power
module
in
a
safe
location.
4.
Within
1
minute,
install
either
another
power
module
or
a
filler
module
into
the
selected
power-module
bay.
Installing
a
power
module
Complete
the
following
steps
to
install
a
power
module
at
the
front
of
the
BladeCenter
T
unit.
The
procedure
is
the
same
for
both
ac-power
and
dc-power
modules.
Attention:
To
help
ensure
proper
cooling
and
system
reliability,
make
sure
that
you
replace
a
removed
power-module
filler
panel
with
a
power
module
within
1
minute.
1.
Note
the
orientation
of
the
power
module
or
filler
you
are
removing;
then,
remove
the
filler
or
power
module
from
the
selected
power-module
bay
and
set
it
aside.
2.
Press
the
blue
release
button
on
the
front
of
the
new
power
module
to
release
the
power-module
handle;
then,
move
the
power-module
handle
outward
until
it
is
in
the
open
position
(90°
from
the
closed
position).
3.
Grip
the
power-module
handle
with
one
hand
and
support
the
bottom
of
the
power
module
with
the
other
hand.
Attention:
Do
not
carry
the
power
module
by
only
the
power-module
handle.
You
must
support
the
weight
of
the
power
module.
4.
Orient
the
new
power
module
to
the
selected
power-module
bay;
then,
slide
the
power
module
into
the
bay
until
it
stops.
5.
Push
the
power-module
handle
in
until
it
locks
into
the
latch
next
to
the
blue
release
button.
6.
Make
sure
the
LEDs
on
the
power
module
indicate
that
it
is
operating
correctly.
Make
sure
that:
v
The
input
power
LED
is
lit.
v
The
output
power
LED
is
lit.
v
The
error
LED
is
not
lit.
7.
If
you
have
other
modules
to
install
at
the
front
of
the
unit,
do
so
now.
Otherwise
reinstall
the
bezel
assembly
at
the
front
of
the
BladeCenter
T
unit.
Chapter
3.
Removing
and
installing
BladeCenter
T
modules
and
options
31
Содержание BladeCenter T Type 8720
Страница 3: ...BladeCenter T Types 8720 and 8730 Installation and User s Guide ERserver...
Страница 8: ...vi BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 28: ...14 BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 64: ...50 BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 74: ...60 BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 88: ...74 BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 122: ...108 BladeCenter T Types 8720 and 8730 Installation and User s Guide...
Страница 127: ......
Страница 128: ...Part Number 88P9320 Printed in USA 1P P N 88P9320...