Service Processor Setup Menu
The following Service Processor Setup Menu is accessed from the Main Menu:
SERVICE PROCESSOR SETUP MENU
1. Change Privileged Access Password
2. Change General Access Password
3. Enable/Disable Console Mirroring:
Currently Enabled
4. Start Talk Mode
5. OS Surveillance Setup Menu
NOT supported in LPAR mode
6. Reset Service Processor
7. Reprogram Flash EPROM Menu
8. Serial Port Snoop Setup Menu
NOT supported in LPAR mode
9. Scan Log Dump Setup Menu:
Currently As Needed
98. Return to Previous Menu
99. Exit from Menus
0>
Note:
Unless otherwise stated in menu responses, settings become effective when a menu is exited using
option 98 or 99.
Passwords
Passwords can be any combination of up to eight alphanumeric characters. You can enter longer
passwords, but the entries are truncated to include only the first eight characters. The privileged-access
password can be set from service processor menus or from System Management Services (SMS) utilities
(see Chapter 8, “Using System Management Services”, on page 407). The general-access password can
be set only from service processor menus.
For security purposes, the service processor counts the number of attempts to enter passwords. The
results of not recognizing a password within this error threshold are different, depending on whether the
attempts are being made locally (at the system) or remotely (through a modem). The error threshold is
three attempts.
If the error threshold is reached by someone entering passwords at the system, the service processor
commands the system to resume the initial program load (IPL). This action is taken based on the
assumption that the system is in an adequately secure location with only authorized users having access.
Such users must still successfully enter a login password to access the operating system.
If the error threshold is reached by someone entering passwords remotely, the service processor
commands the system to power off to prevent potential security attacks on the system by unauthorized
remote users. The following table lists what you can access with the privileged-access password and the
general-access password.
Chapter 7. Using the Service Processor
367
Содержание @Server pSeries 630 6C4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 541: ...Chapter 10 Parts Information 521...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 649: ......
Страница 650: ...Printed in U S A May 2003 SA38 0604 03...