![IBM @Server pSeries 630 6C4 Скачать руководство пользователя страница 262](http://html2.mh-extra.com/html/ibm/atserver-pseries-630-6c4/atserver-pseries-630-6c4_service-manual_3350365262.webp)
Table 4. Firmware Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
25A8 0999 NVRAMRC script evaluation error - stack
unbalanced on completion
This is a firmware debug environment error.
There is no user action or FRU replacement for
this error.
25A8 0A00 Unable to retrieve NVRAM LPAR table
information
Refer to the actions column for error code 25A8
0xxx.
Memory Error Notes
Use the location code obtained from the SMS Error Log utility (described in “Error Log Utility Procedure” on
page 335) to identify which memory DIMM (or memory DIMM quad) the error is reported against.
Memory error codes are in the form
25Cyyxxx
where
yy
indicates memory DIMM present detect-bits (PD-bits) and
xxx
indicates the last 3 digits of the error code.
See “Memory DIMM Present Detect Bits (PD-Bits)” on page 334 for information on how to interpret PD bits.
25B0 0001 No memory DIMMs detected.
Go to “MAP 1240: Memory Problem Resolution”
on page 73.
25B0 0004 Multiple memory DIMMs failed a memory test.
Go to “MAP 1240: Memory Problem Resolution”
on page 73.
25Cy y001 DIMM is not supported
Replace unsupported DIMM(s).
Note:
Memory DIMMs must be replaced with a
supported type of memory DIMM. If an
unsupported type of memory DIMM is replaced
with the same unsupported type, the error
persists.
See the
″
Memory Error Notes
″
on page 242 for
more information.
25Cy y002 Memory DIMM fails memory test.
Go to “MAP 1240: Memory Problem Resolution”
on page 73.
2602 0001
Description:
Invalid PCI adapter vendor ID
Action:
Attention:
Before moving the adapter to another slot, verify with the customer or system
administrator that the slot that the adapter is being moved to is available to the partition in which
the adapter presently resides.
1. Move adapter to another slot (behind a different PCI bus).
2. Check for available firmware updates for adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply if update available.
6. If the card is in the system drawer, replace the PCI riser card, location: U0.1-P2. If the card is
in an I/O subsystem, replace the I/O backplane that contains the slot in which the adapter
was originally installed, location: U0.
dd
-P1.
242
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Содержание @Server pSeries 630 6C4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 541: ...Chapter 10 Parts Information 521...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 649: ......
Страница 650: ...Printed in U S A May 2003 SA38 0604 03...