SPCN Error Codes
Attention:
If a power supply or fan is hot-swapped, wait five minutes, then recheck the operating system
error log. If the system has to be shut down to replace a power supply or fan, reboot the system, wait five
minutes after the operating system login prompt appears, then recheck the operating system error log. If
the detailed information for the most recent error with the same identifier indicates that the original problem
has not been fixed by performing the first action in the action column, continue with the next action in the
action column.
Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to “MAP
1548: Processor Subsystem Problem Isolation” on page 139 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries Diagnostic Information for Multiple Bus Systems
.
Table 2. SPCN Error Codes for the CEC (system unit)
Error Code Description
Action/
Possible Failing FRU
1011 00AC AC loss or brownout detected
Informational
1011 00EF Room emergency power off detected
Informational
1011 1510 Power supply 1 power source failure
1. Check input power to the power supply
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1511 Power supply 1 fault
1. Verify that the media support shelf is installed
and properly seated.
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1512 Power supply 1 non-power fault
1. System power supply 1
Location: U0.1-V1
2. CEC backplane
Location: U0.1-P1
1011 1513 Power supply 1 domain fault
1. Verify that the media support shelf is installed
and properly seated.
2. System power supply 1
Location: U0.1-V1
3. CEC backplane
Location: U0.1-P1
1011 1520 Power supply 2 power source failure
1. Check input power to power supply 2
2. System power supply 2
Location: U0.1-V2
3. CEC backplane
Location: U0.1-P1
1011 1521 Power supply 2 fault
1. System power supply 2
Location: U0.1-V2
2. CEC backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
217
Содержание @Server pSeries 630 6C4
Страница 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver...
Страница 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 535: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 630 Model 6C4 and Model 6E4 515...
Страница 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 541: ...Chapter 10 Parts Information 521...
Страница 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide...
Страница 649: ......
Страница 650: ...Printed in U S A May 2003 SA38 0604 03...