Table 69. Noise emissions
1, 2, 3
(continued)
Product description Declared A-weighted sound power level,
L
Wad
(B)
Declared A-weighted sound pressure
level, L
pAm
(dB)
Model 7063-CR1 (1-
socket) at maximum
temperature with
acoustical doors
(front and rear), FC
EC08 and FC EC07,
installed.
7.9
4, 5
7.9
4, 5
63
63
Notes:
1. Declared level L
Wad
is the upper-limit A-weighted sound power level. Declared level L
pAm
is the mean A-
weighted emission sound pressure level that is measured at the 1-meter bystander positions.
2. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. 10 dB (decibel) equals 1 B (bel).
4. Under certain environments, configurations, system settings, and workloads, fan speeds are increased that
result in higher noise levels.
5. Notice: Government regulations (such as those prescribed by OSHA or European Community Directives)
might govern noise level exposure in the workplace and might apply to you and your server installation. This
IBM system is available with an optional acoustical door feature that can help reduce the noise that is
emitted from this system. The actual sound pressure levels in your installation depend upon various factors,
including the number of racks in the installation; the size, materials, and configuration of the room where
you designate the racks to be installed; the noise levels from other equipment; the room ambient
temperature, and employees' location in relation to the equipment. Further, compliance with such
government regulations also depends upon various extra factors, including the duration of employees'
exposure and whether employees wear hearing protection. IBM recommends that you consult with
qualified experts in this field to determine whether you are in compliance with the applicable regulations.
Electromagnetic compatibility compliance: CISPR 22:2008; CISPR 32:2012, CNS 13438 (Taiwan); EN
55032:2012 (EU, Australia); EN 55024:2010 (EU); EN 61000-3-2:2014 (EU, Japan); EN 61000-3-3:2013
(EU); FCC, Title 47, Part 15 (USA); GB 9254-2008 (China); GB 17625.1-2012 (China); GB 17625.2-2007
(China); ГОСТ 30804.3.2-2013 (IEC 61000-3-2:2009) (EAEU); ГОСТ 30804.3.3-2013 (IEC
61000-3-3:2008) (EAEU); ГОСТ 30805.22-2013 (CISPR 22:2006) (EAEU); ГОСТ CISPR 24-2013 (EAEU);
ICES-003, Issue 6, January 2016 (Canada); KN 32:2015 (Korea); KN 35:2015 (Korea); TCVN 7189:2009
(Vietnam); VCCI, April 2015 (Japan)
Safety compliance: UL 60950-1, 2nd Edition, 2014-10-14; CAN/CSA C22.2 No. 60950-1-07, 2nd
Edition, 2014-10, IEC 60950-1:2005 (Second Edition); Am1:2009 + Am2:2013; EN 60950-1:2006 +
A1:2010 + A11:2009 + A12:2011 + A2:2013
Rack switch specifications
Rack switch specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Select the appropriate models to view the specifications for your rack switch.
Site and hardware planning 67
Содержание 9008-22L
Страница 1: ...Power Systems Site and hardware planning IBM...
Страница 4: ...iv...
Страница 14: ...xiv Power Systems Site and hardware planning...
Страница 16: ...2 Power Systems Site and hardware planning...
Страница 20: ...6 Power Systems Site and hardware planning...
Страница 40: ...Figure 1 FC EPB8 power distribution panel 26 Power Systems Site and hardware planning...
Страница 49: ...Figure 5 FC ERG0 rear rack extender top down view Site and hardware planning 35...
Страница 123: ...Figure 35 Cable management bridge lances Site and hardware planning 109...
Страница 163: ......
Страница 164: ...IBM...