Table 13. System characteristics
System characteristics
Properties
Product type
Computer server
Year first manufactured
2018
Noise levels (declared A-weighted sound
power level of the computer)
8.3 bels (B)
Table 14. Power characteristics
1
Power characteristics
Properties
Internal/external power supply efficiency
80 PLUS Verification and Testing Report 1025 W
80 PLUS Verification and Testing Report 1400 W
Maximum power (watts)
1400 W and 1025 W
Idle state power (watts)
Unavailable
Sleep mode power (watts)
N/A for servers
1. Preliminary data is based on development systems and is subject to change.
Table 15. Test parameters for measurements
Test parameters
Properties
Test voltage and frequency
230 V ac at 50 or 60 Hz
Total harmonic distortion of the electricity
supply system
The maximum harmonic content of the input voltage waveform
is equal to or less than 2%. The qualification is compliant with
EN 61000-3-2.
Information and documentation on the
instrumentation setup and circuits that are
used for electrical testing
ENERGY STAR Test Method for Computer Servers; ECOVA
Generalized Test Protocol for Calculating the Energy Efficiency
of Internal Ac-Dc and Dc-Dc Power Supplies
Measurement methodology that is used to
determine information in this document
ENERGY STAR Servers Version 2.0 Program Requirements;
ECOVA Generalized Test Protocol for Calculating the Energy
Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies
Model 9009-41A, 9009-42A, and 9223-42H Technical Documentation for EU Regulation 617/2013
International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/
IBM Power Systems
Site and hardware planning 17
Содержание 9008-22L
Страница 1: ...Power Systems Site and hardware planning IBM...
Страница 4: ...iv...
Страница 14: ...xiv Power Systems Site and hardware planning...
Страница 16: ...2 Power Systems Site and hardware planning...
Страница 20: ...6 Power Systems Site and hardware planning...
Страница 40: ...Figure 1 FC EPB8 power distribution panel 26 Power Systems Site and hardware planning...
Страница 49: ...Figure 5 FC ERG0 rear rack extender top down view Site and hardware planning 35...
Страница 123: ...Figure 35 Cable management bridge lances Site and hardware planning 109...
Страница 163: ......
Страница 164: ...IBM...