Step 4. Unplug the flexible circuit
3
from the operator panel.
Note: If mainline electrical power is present in the 7133, and the 7133 power
is set to Standby by the power switch or by the remote-power-control
unit, the internal dc power switches on when the flexible circuit is
disconnected from the operator panel. The dc power remains switched
on when the circuit is reconnected.
Step 5. Unscrew the screws
1
.
Step 6. Pull off the operator panel assembly
2
.
Step 7. Replace parts in the reverse sequence.