SRN
FRU List
Problem
D0102
None
Description: The command line diagnostics have detected
that the device is reserved or fenced out.
Action: Use the -u flag to break the reservation or fence.
Warning: If another using system is using this device,
unpredictable results might occur if you break the
reservation or fence.
D0103
None
Description: The diagnostics attempted to break a
reservation, but this adapter does not provide support for
the function.
Action: A different adapter is using the disk drive module.
Release the disk drive module, and run the diagnostics
again.
D0200
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The disk drive module timed out while the
diagnostics were running.
Action: Rerun the diagnostics. If the problem remains,
exchange the FRU for a new FRU.
D0300
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The disk drive module failed the diagnostic test.
Action: Exchange the FRU for a new FRU.
D0400
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The disk drive module is not ready while the
diagnostics are running.
Action: Rerun the diagnostics. If the problem remains,
exchange the FRU for a new FRU.
D0450
None
Description: A Format operation is in progress.
Action: The Format operation that was started on this disk
drive module has not yet finished.
A Format operation can take up to 30 minutes to run. Wait
for it to finish before you run the diagnostics again. You can
observe the progress of the Format operation by running the
Format service aid again on this disk drive module.
D0460
None
Description: A Format operation has been degraded.
Action: The Format operation that was started on this disk
drive module did not finish. Possibly, the disk drive module
was switched off while the Format operation was running.
Run the Format service aid to format this disk drive module.
D4000
to
D6PAA
Not applicable
Description: SRNs in this range are not enclosure
(subsystem) SRNs.
Action: For SRNs in this range, see the documentation for
your SSA attachment.
84
7133 Models D40 and T40 Service Guide
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...