SRN
FRU List
Problem
21PAA
to
29PAA
Disk-drive module (45%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
SSA attachment (45%) (using-system
Installation and Service Guide).
External SSA cables, optical
extenders, or main fibre optic cables
(6%).
Frame assembly (2%) (“Frame
Assembly” on page 208).
Bypass card (2%) (“Bypass (SNBC)
Cards” on page 201).
Description: An SSA ‘Threshold exceeded’ link error has
been detected.
Action: Go to the Intermittent Link Error MAP in the user or
maintenance information for your using-system SSA
attachment.
2A002
Disk-drive module (50%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
SSA attachment (50%) (using-system
Installation and Service Guide).
Description: Async code 02 has been received. Probably, a
software error has occurred.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system before exchanging any FRUs.
2A003
Disk-drive module (50%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
SSA attachment (50%) (using-system
Installation and Service Guide).
Description: Async code 03 has been received. Probably, a
software error has occurred.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system before exchanging any FRUs.
2A004
Disk-drive module (50%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
SSA attachment (50%) (using-system
Installation and Service Guide).
Description: Async code 04 has been received. Probably, a
software error has occurred.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system before exchanging any FRUs.
2A005
2A006
2A106
Power supply assembly (46%)
(“Power Supply Assemblies” on
page 162).
Fan assembly (46%) (“Fan Assemblies”
Controller card asm (5%) (“Controller
Card Assembly” on page 199).
Frame assembly (3%) (“Frame
Assembly” on page 208).
Description: Async code 06 has been received. This code
indicates that one or more disk drive modules have detected
the loss of redundant power or cooling.
Action: Go to “MAP 2010: 7133 Models D40 and T40 –
START” on page 87 to further isolate the problem.
78
7133 Models D40 and T40 Service Guide
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...