a. Exchange, for new FRUs, the appropriate FRUs of the device
(see the service information for the device).
b. Check the power source of the device.
c. Go to “MAP 2410: 7133 Models D40 and T40 – Repair
Verification” on page 131 to verify the repair.
YES
a. Exchange the optical extender for a new one.
b. Go to “MAP 2410: 7133 Models D40 and T40 – Repair
Verification” on page 131 to verify the repair.
c. If the problem remains, continue with this step.
v
If the new optical extender that you have just installed is
plugged into a 7133, exchange, in the sequence shown, the
following FRUs for new FRUs. Ensure that for each FRU
exchange, you go to “MAP 2410: 7133 Models D40 and T40 –
Repair Verification” on page 131 to verify the repair.
1) The first disk drive module in the string whose connector
you have just checked (see “Disk Drive Modules and
Dummy Disk Drive Modules” on page 150).
For information about disk drive module strings, see
“Internal Connections (Model D40)” on page 28 or “Internal
Connections (Model T40)” on page 30.
2) If present, the dummy disk drive modules that are between
the connector and the first disk drive module of the string
(see “Disk Drive Modules and Dummy Disk Drive Modules”
3) The bypass card into which the new optical extender is
plugged (see “Bypass (SNBC) Cards” on page 201).
v
If the new optical extender that you have just installed is
plugged into an SSA attachment:
1) Exchange that attachment for a new one (see the
Installation and Service Guide, or equivalent, for the using
system).
2) Go to “MAP 2410: 7133 Models D40 and T40 – Repair
Verification” on page 131 to verify the repair.
v
If the new optical extender that you have just installed is
plugged into some other device:
1) Exchange, for new FRUs, the appropriate FRUs of the
device (see the service information for the device).
2) Go to “MAP 2410: 7133 Models D40 and T40 – Repair
Verification” on page 131 to verify the repair.
114
7133 Models D40 and T40 Service Guide
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...