SRN
FRU List
Problem
2A206
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: A disk drive module has detected that one of its
SSA links has failed the POSTs.
Action: Use a link verification, or physical view, service aid
to determine where the SSA link is broken (see the user or
maintenance information for your using-system SSA
attachment). Run concurrent diagnostics to the two disk
drive modules that are nearest to, and on each side of, the
place where the link is broken. The diagnostics show which
disk drive module detected the problem. For information
about how run concurrent diagnostics, see Concurrent
Diagnostics in the “Additional Information” appendix (in this
book) for your using system.
2FFFF
None
Description: An async code that is not valid has been
received.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system.
300C0
301C0
Power supply assembly (46%)
(“Power Supply Assemblies” on
page 162).
Fan assembly (46%) (“Fan Assemblies”
Controller card asm (5%) (“Controller
Card Assembly” on page 199).
Frame assembly (3%) (“Frame
Assembly” on page 208).
Description: A health check has reported that one or more
disk drive modules have detected the loss of redundant
power or cooling.
Action: Go to “MAP 2010: 7133 Models D40 and T40 –
START” on page 87 to further isolate the problem.
303FE
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: A disk drive module has reported a microcode
error.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system before exchanging any FRUs.
303FF
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: A SCSI status that is not valid has been
received.
Action: Go to Software and Microcode Errors in the
“Additional Information” appendix (in this book) for your
using system before exchanging any FRUs.
31000
Disk drive module (100%) (“Disk Drive
Modules and Dummy Disk Drive
Modules” on page 150).
Description: The disk drive has been reset by the
attachment. The disk drive might be going to fail.
Action: If the disk drive can still be accessed, the user
should create a backup of all the data from this disk drive,
then remove the disk drive from the system configuration.
Exchange the FRU for a new FRU.
Chapter 2. Problem Determination Procedures
79
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...