Enclosure Environment
01|ENCLOSURE ENVIRONMENT
XXXXXX
02|
03|SSA Enclosure Environment for:
04| R1E1
Enclosure 1
SSA Enclosure
05|
06| Enclosure Element
Status
07|
08| Power Unit 1
Good
09| Power Unit 2
Fault (exchanged)
10|
11| Fan Unit 1
Good
12| Fan Unit 2
Good
13| Fan Unit 3
Fault
14|
15| Operator Panel
Not Present
16|
17| Remote Power Off Module (RPO)
Good
18|
19| Ambient Temperature (degrees Celsius)
35
20|
21| Controller
Fault
22|
23|
24| F3=Cancel
F10=Exit
25|
Note: In this screen, the word “exchanged” indicates that the FRU has been removed
and reinstalled, or exchanged for a new FRU, since the “Exchanged” flag was
last reset.
Keys to Use
v
Press Enter to return.
v
Press the Cancel key to return to the Enclosure Selection (environment) menu.
v
Press the Exit key to return to the Service Aid Selection menu.
264
7133 Models D40 and T40 Service Guide
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...