9. Refer to Figure 38.
10. Check for continuity between the frame of the 7133 and the ground pin
1
of
each mainline-power connector.
11. Go to step 15.
12. Refer to Figure 39.
13. Check for continuity between the frame of the 7133 and the ground pins 1 and 7
of each mainline-power connector.
14. Go to step 15.
15. If any power supply assembly has no continuity, exchange that power supply
assembly for a new one (see “Power Supply Assemblies” on page 162), then do
the complete grounding check again.
If each power supply assembly has continuity, you might have a problem with the
power cable or with the grounding of the using system.
If you are servicing a 220-volt 7133, go to step 16.
If you are servicing a −48 volt 7133, see the rack, or using-system, Installation and
Service Guide, or equivalent, to isolate the fault, then do the complete grounding
check again.
16. Check the power cable for continuity.
1
Figure 38. Ground Pin (Model D40: 220 V)
Pin 1
Pin 7
Pin 12
Pin 6
Figure 39. Ground Pins (Model D40: −48 V)
Chapter 1. Reference Information
67
Содержание 7133 D40
Страница 1: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 2: ......
Страница 3: ...7133 Models D40 and T40 Serial Disk Systems Service Guide GY33 0192 07 ...
Страница 10: ...viii 7133 Models D40 and T40 Service Guide ...
Страница 14: ...xii 7133 Models D40 and T40 Service Guide ...
Страница 90: ...72 7133 Models D40 and T40 Service Guide ...
Страница 260: ...Assembly 1 7133 Model D40 242 7133 Models D40 and T40 Service Guide ...
Страница 262: ...Assembly 1 continued 244 7133 Models D40 and T40 Service Guide ...
Страница 264: ...Assembly 1 continued 246 7133 Models D40 and T40 Service Guide ...
Страница 292: ...274 7133 Models D40 and T40 Service Guide ...
Страница 305: ......
Страница 306: ...Part Number 18P6104 Printed in the U S A GY33 0192 07 1P P N 18P6104 ...