10.2.2 Compatibility mode 32Mbit with ibaBM-DP device module
In compatibility mode 32Mbit, the device can be used with an
ibaBM-DP device module
in the ibaPDA configuration ( I/O Manager).
This mode is necessary when you want to connect an ibaBM-DP device to an ibaPDA
system, but cannot establish a bidirectional FO cable connection. One reason might be
e. g. that you have only ibaFOB-D cards with inputs and outputs cannot be added any-
more due to a lack of space.
This is why the commissioning procedure is different from the procedure described in
chapter 10.1.
The following prerequisites have to be met:
ibaPDA version V6.32.0 or higher
The rotary switch on the device has to be set to S1 = 1 and S2 = 0
(see chapter 7.3.4.2).
The following connections have to be established:
Unidirectional FO connection between the transmission output TX-X10 of ibaBM-DP
and a free input of an ibaFOB-D card in the ibaPDA-PC.
For this application, ibaBM-DP has to be connected via X22 to the Ethernet net-
work. For this purpose, you have to set an appropriate IP address.
Connection to the PROFIBUS network via X40 and/or X41.
Notes on the configuration in the ibaPDA I/O Manager:
1.
Select the correct ibaFOB-D card and mark the link ibaBM-DP is connected to.
2.
Click on the link with the right mouse button and choose "Autodetect". The device is
identified automatically and displayed in the module tree.