ibaBM-DP
Manual
Issue 1.7
55
10
Configuration with ibaPDA
For measuring and recording data over ibaBM-DP in 32Mbit Flex mode, you need
ibaPDA version 6.32.0 or higher.
For measuring and recording data over ibaBM-DP in compatibility mode 32Mbit, you
need ibaPDA version 6.20.2 or higher.
For ibaPDA versions older than version 6.32.0, you can use the device module
ibaBM-DPM-S for I/O configuration. For a description, please see the "ibaBM-DPM-S“
manual.
When changing the slave configuration of the ibaBM-DP device (add, delete active
slaves or transferring them on another bus) during operation, this results in a temporal
decoupling of the slaves from the PROFIBUS. The communication to the DP master is
interrupted. If the PLC (e .g. SIMATIC S7
®
) is not secured by OBs, this will result in a
stop of the PLC!
When changing addresses and data within slaves that have been already defined, there
will be no disturbances in the PROFIBUS communication!
For preventing disturbances on the PROFIBUS, use for active slaves only free slave
numbers that are not used by other devices!
10.1 First steps in ibaPDA configuration
By means of the following instruction, you learn how to integrate ibaBM-DP step by step
into ibaPDA and how to configure measurement signals. The description refers to the
32Mbit Flex mode
(see chapters 7.3.4.3 and 8.1). In chapter 10.2 we describe special
features and deviations which have to be considered in compatibility mode 32Mbit.
Note
Make sure that 32Mbit Flex mode has been selected using the S1 and S2 rotary
switches (see chapter 7.3.4.3).
The basic device settings like network settings, passwords etc. should be done in ad-
vance via the web interface.
With ibaPDA, you can define the PROFIBUS slave addresses and configure analog
and digital measurement signals. The following description refers to ibaPDA version
6.32.0 or higher.
1.
Connect the device to a voltage source and switch on the device (see chapters 7.3.2).
2.
Establish a FO connection between the TX connector of the device and a free RX
input of an ibaFOB-D card as well as a FO connection between the RX connector
and a free TX output of the ibaFOB-D card.
The TX/RX connectors of the ibaFOB-D card belong together in pairs, i.e. you cannot