Manual
ibaBM-DP
58
Issue 1.7
8.
Please decide, if you want ibaBM-DP to work with active slaves and/or only as
sniffer. If the device is to be connected with one or more active slaves to the PRO-
FIBUS, you first have to configure the PROFIBUS on the PLC side for defining the
slave numbers of the active slaves of the device (see chapter 11.2). Moreover, the
PROFIBUS parameters of all participants are needed, you want to measure data
from (slave no., length of inputs and outputs and data types). These are also
needed for the pure sniffer operation.
9.
Add a module under the ibaBM-DP device module. Click with the right mousebutton
on the ibaBM-DP device module and select in the context menu "Add module" the
wanted module from the list.
Optionally, for adding a module, you can also select the option “Click to add mod-
ule…” marked in blue under the bus connection. Depending on the license, the fol-
lowing modules are available:
Active slave, Sniffer, Active slave decoder, Sniffer decoder, Slave diagnostics,
Bus diagnostics
With additional ibaPDA license: S7 Request, S7 Request Decoder, FM458 Re-
quest, TDC Request. For information regarding these modules, please read the
respective manuals.