139
Part 2 Programs
SSPG (Pause program)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
SSPG
Program
number
(Program
number)
CC
[Function] Pause the program from the one specified in operand 1 through the other specified in
operand 2, at the current step. Specification in operand 1 only is allowed.
(Note 1)
Pausing a program will also pause the operation the program has been executing.
(Note 2)
Not only the operation but also the execution of the step itself will be paused.
[Example 1]
SSPG
10
12
Pause program Nos. 10, 11 and 12 at the current step.
Error-generation/output-operation conditions
When one SSPG program is specified (only operand 1 is specified)
No program number error *1
Program already registered
Status of the
specified program
Program running
Program not
running
Program not yet
registered
Program number
error *1
Error None
None
C03
“Non-registered program
specification error”
C2C
“Program number
error”
Output operation
ON
OFF
OFF
OFF
* The errors shown in the table represent those that generate in accordance with the status of the specified program.
Errors caused by other factors are excluded.
* 1 --- Program number error indicates specification of a number smaller than 1 or exceeding 64.
When multiple SSPG programs are specified (both operands 1 and 2 are specified)
No program number error *2
Registered program exists inside the
specified range *3
Status of the
specified program
Running program
exists inside the
specified range *4
None of programs
inside the specified
range are running
None of programs inside
the specified range are
registered
Program
number error *1
Error None None
C03
“Non-registered program
specification error”
C2C
“Program
number error”
Output operation
ON
OFF
OFF
OFF
* The errors shown in the table represent those that generate in accordance with the status of the specified program.
Errors caused by other factors are excluded.
* 2 --- Program number error indicates specification of a number smaller than 1 or exceeding 64.
* 3 --- In this case, non-registered programs inside the specified range are not treated as a target of operation with
EXPG, ABPG, SSPG and PSPG commands. This will not affect error generation or output operation.
* 4 --- In this case, programs not running (but already registered) inside the specified range are not treated as a
target of operation with SSPG and RSPG commands. This will not affect error generation or output operation.
Program No. 10
Program No. 11
Program No. 12
Currently executed step
Currently executed step
Currently executed step
SSPG