452
Appendi
x
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
D58
Fieldbus error (INIT timeout)
An INIT timeout was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D59
Fieldbus error (DPRAM write/read)
A DPRAM write/read error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5A
Fieldbus error (TOGGLE timeout)
A TOGGLE timeout was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5B
Fieldbus error (Access-privilege retry over)
An access-privilege retry over error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5C
Fieldbus error (Access-privilege open error)
An access-privilege open error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5D
Fieldbus error (FBRS link error)
A FBRS link error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D5E
Fieldbus error (Mailbox response)
A mailbox response error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.
D67
Motor/encoder configuration information mismatch error
The “motor/encoder configuration information” (motor identification number and
encoder identification number) in driver parameter No. 26 does not match the
“motor/ encoder configuration information” (motor identification number and
encoder identification number) in encoder parameter No. 11. Check the
parameter values, encoder cable connection, etc.
D68
No remote-mode control support board error
Hardware supporting remote-mode control is not installed, although remote-mode
control (AUTO/MANU) is specified in I/O parameter No. 79.
D69
External terminal block overcurrent or power-supply error
Overcurrent or power-supply error in the external terminal block
D6A
Hardware unsupported function error
An attempt was made to use a function not supported by the hardware.
D6B
Overrun error
The overrun sensor was actuated.
D6C
Actual-position soft limit over error
The actual position exceeded a soft limit by the “soft limit/actual position margin”
or more.
D6D
Logic error
A logic error occurred.