457
Appendi
x
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
E77
Magnetic-pole sensor installation specification mismatch error
The magnetic-sensor installation specification in the system’s axis-specific
parameter and that of the installed encoder do not match.
E78
Brake installation specification mismatch error
The brake installation specification in the system’s axis-specific parameter and
that of the installed encoder do not match.
E79
Abnormal response error when sending EEPROM-data setting slave
command
An abnormal response was received when an EEPROM-data setting slave
command was sent.
E7A
Maximum receive size over error when sending EEPROM-data
setting slave command
The receive size exceeded the limit value when an EEPROM-data setting slave
command was sent.
E7B
Motor-drive power ON timeout error
Abnormal current flow from the motor-drive power source
E7C
Register read/write test error
Error reading/writing the register
E7D
Linear-movement axis parameter error
Check axis-specific parameter Nos. 38, 68, 1, etc.
E7E
Parameter error
The parameter is invalid.
E7F
Stroke parameter error
Check axis-specific parameter Nos. 7, 8, 1, etc.
E80
Unsupported card error
An unsupported card is installed in an I/O slot.
E81
Priority auto-assignment card non-detection error
Priority auto-assignment card cannot be detected.
E82
Card mismatch error
The combination or positioning of I/O slot cards has a problem.
E83
I/O slot card error
The I/O slot card is invalid.
E84
Resolution parameter error
Check axis-specific parameter Nos. 47, 50, 51, 44, 42, 43, 1, 37, etc.
E85
Driver ready OFF factor indeterminable error
Driver ready OFF factor cannot be determined.
E86
Fieldbus error (FBVCCER)
A fieldbus error (FBVCCER) was detected.
E87
Fieldbus error (FBPOWER)
A fieldbus error (FBPOWER) was detected.
E88
Power error (Other)
A power error (Other) was detected. This error also generates when the power
OFF
ON interval is short. After the power has been turned off, be sure to wait
for at least 5 seconds before turning it back on. Abnormal regenerative resistance
temperature is also suspected.
E89
SCIF open error in non-AUTO mode (Servo in use)
In a mode other than AUTO, opening of the serial 1 channel (also used by the PC
software/TP port) from a SEL program is prohibited while the servo is in use (to
ensure safety).
E8A
SEL program flash-ROM status error
Data is not written to the flash ROM correctly or written in an old, incompatible
application version.
E8B
Symbol definition table flash-ROM status error
Data is not written to the flash ROM correctly or written in an old, incompatible
application version.
E8C
Point data flash-ROM status error
Data is not written to the flash ROM correctly or written in an old, incompatible
application version.
E8D
Parameter flash-ROM status error
Data is not written to the flash ROM correctly or written in an old, incompatible
application version.
Содержание ssel
Страница 1: ...Operation Manual Eighth Edition SSEL Controller ...
Страница 26: ......
Страница 50: ...25 Part 1 Installation 3 Specification with system memory backup battery optional ...
Страница 385: ...359 ...
Страница 495: ......
Страница 496: ......