186
Part 2 Programs
PTRQ (Change push torque limit parameter)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional Optional
PTRQ
Axis
pattern
Ratio CC
[Function] Change the push torque limit parameter of the axis pattern specified in operand 1 to the value
in operand 2. Operand 2 is set as an integer (unit: %).
A PTRQ command temporarily rewrites “Driver parameter No. 38: Push torque limit at
positioning.”
(Note 1)
If a push torque limit is not set by a PTRQ command, the value set in “Driver parameter No.
38: Push torque limit at positioning” will be used.
(Note 2)
The new push torque limit will remain effective even after the program ends. Therefore, when
building a system using the PTRQ command, in every program explicitly specify a push
torque limit using a PTRQ command before each push-motion operation. Assuming that the
push torque limit will be reset to the original value when push-motion operation ends in one
program can cause an unexpected problem in another program, because a different push
torque limit will be used if the program is aborted due to an error, etc.
(Note 3)
The new value set by a PTRQ command will become ineffective after a power-on reset or
software reset.
(Note 4)
A PTRQ command does not rewrite “Driver parameter No. 38: Push torque limit at
positioning” (main CPU flash memory (non-volatile memory)).
[Example]
PTRQ
1
50
Change the push torque limit parameter for axis 1 to 50%.
PAPR
100
20
Set the push-motion approach distance to 100 mm and the
push-motion approach speed to 20 mm/sec.
MOVP
2
Move to position No. 2.
PUSH
10
Move by push motion from position No. 2 to position No. 10.