463
Appendix
Troubleshooting of SSEL Controller
The X-SEL controller has a panel window on its front side.
This panel window displays an error number every time an error generates.
When the power is turned on, normally “rdy” or “Ardy” will be displayed. “P01” or other code will be displayed
while a program is running.
When an error generates, the panel window will show “EA1D” or other code starting with “E.” (Some errors do
not begin with “E.”)
Status
Panel window display
After turning on the power
rdy, Ardy
Program is running
P01, P64, etc.
Error has generated
EA1D, ED03, etc.
* Among the alphabets, B and D are shown in lower case.
Depending on the error number, it may be possible to reset the error after removing the cause of the error, or the
power must be reconnected to reset the error.
Also, some error numbers are output to the LED display in the panel window, while others are not.
For details, see “
Error Level Control.”