24
2. XSEL-J/K/P/Q/JX/KX/PX/QX
I/O parameters for XSEL J/K types
No.
Parameter name
Default value
(reference)
Input
range
Setting
Remarks
1 I/O port assignment type
0
0 ~ 20
0
0: Fixed assignment
1: Automatic assignment (Priority:
Assigned from slot 1)
* Ports are assigned consecutively only
for slots where a board is physically
installed, starting from slot 1, for safety
reasons.
2 Input port start number for standard I/O
based on fixed assignment (I/O1)
000
-1 ~ 299
000
0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
3 Output port start number for standard
I/O based on fixed assignment (I/O1)
300
entered with a negative sign.)
4 Input port start number for expansion
I/O1 based on fixed assignment (I/O2)
-1
-1 ~ 299
256
0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
(Slot immediately next to the standard I/O
slot)
5 Output port start number for expansion
I/O1 based on fixed assignment (I/O2)
-1
entered with a negative sign.)
6 Input port start number for expansion
I/O2 based on fixed assignment (I/O3)
-1
-1 ~ 299
-1
0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
7 Output port start number for expansion
I/O2 based on fixed assignment (I/O3)
-1
entered with a negative sign.)
8 Input port start number for expansion
I/O3 based on fixed assignment (I/O4)
-1
-1 ~ 299
-1
0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
9 Output port start number for expansion
I/O3 based on fixed assignment (I/O4)
-1
entered with a negative sign.)
10 Error monitor for standard I/O (I/O1)
2
0 ~ 5
2
11 Error monitor for expansion I/O1 (I/O2)
1
0 ~ 5
1
12 Error monitor for standard I/O2 (I/O3)
0
0 ~ 5
0
13 Error monitor for expansion I/O3 (I/O4)
0
0 ~ 5
0
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power
supply errors)
(Main application version 0.55
or later)
3: Monitor (Monitor 24-V I/O power supply
errors only)
14 Number of ports used for remote input
via network I/F card
64
0 ~ 256
256
Multiple of 16
15 Number of ports used for remote output
via network I/F card
64
0 ~ 256
256
Multiple of 16
I/O1 through I/O4 indicate slot numbers.
-1
300 ~ 599
-1
300 ~ 599
300
300 + (multiple of 8) (Invalid, if a value is
556
300 + (multiple of 8) (Invalid, if a value is
-1
300 ~ 599
-1
300 + (multiple of 8) (Invalid, if a value is
-1
300 ~ 599
-1
300 + (multiple of 8) (Invalid, if a value is
122
14H
0H ~
FFFFFFFFH
Optional
Network attribute 3
Bits 0 to 11:
"PC/TP Reconnection Latency at Software
Reset" added time (sec) when fieldbus in use
* Valid Values from 0 to 500 (sec)
(XSEL-J/K: Main application of Ver.1.16 or later
XSEL-JX/KX: Main application of Ver.0.51 or later)
Содержание DeviceNet MSEL Series
Страница 1: ...Operation Manual Twenty Fourth Edition XSEL TT MSEL TTA SSEL SCON C ASEL E Con PSEL RCS C ...
Страница 2: ......
Страница 16: ...8 8 ...
Страница 93: ...85 5 Tabletop Robot TTA 㻌 ...
Страница 142: ...134 ...
Страница 143: ......