40
3. XSEL-R(A)/S(A)/R(A)X/S(A)X/R(A)XD/S(A)XD
34
2.6 I/O Port Numbers for X-SEL
The table below lists the standard I/O port numbers for X-SEL controllers.
On X-SEL controllers, port numbers and function assignments can be changed using I/O parameters. (For
details, refer to the “Operation Manual for X-SEL Controller.”)
Port No.
Function
Port No.
Function
000
Program start
300
Alarm output
001
General-purpose input
301
Ready output
002
General-purpose input
302
Emergency stop output
003
General-purpose input
303
General-purpose output
004
General-purpose input
304
General-purpose output
005
General-purpose input
305
General-purpose output
006
General-purpose input
306
General-purpose output
007
Program specification (PRG No. 1)
307
General-purpose output
008
Program specification (PRG No. 2)
308
General-purpose output
009
Program specification (PRG No. 4)
309
General-purpose output
010
Program specification (PRG No. 8)
310
General-purpose output
011
Program specification (PRG No. 10)
311
General-purpose output
012
Program specification (PRG No. 20)
312
General-purpose output
013
Program specification (PRG No. 40)
313
General-purpose output
014
General-purpose input
314
General-purpose output
015
General-purpose input
315
General-purpose output
Input
Output
(Note) The numbers of I/O ports are as follows:
If DeviceNet and expansion I/O boards are used together, pay attention to the numbers of I/O
ports.
Inputs: 000 to 299 (maximum of 300 points)
Outputs: 300 to 599 (maximum of 300 points)
3.3 DeviceNet Interface
(1) Name of Each Part
Pin Color
Description
Red
Positive side of communication
power line
White
High side of signals
No color
Shield
Blue
Low side of signals
Black
Negative side of communication
power line
(2) Monitor LED Indicators
The board operation status and network condition are obtained with the two LEDs located in the front of
the communication board.
○: Illuminating ×: OFF
☆ :
Flashing
LED
Color
Indication Status
Indication Description (Detailed Explanation)
NS
(Network
Status)
Green
○
•
Online, Communication in normal condition
☆
•
Online, No connection established
Orange
○
•
Critical link error
☆
•
Connection timeout
Green/
Orange
Blink by turn
•
Self-testing
─
×
•
Offline / No power supply confirmed
MS
(Module
Status)
Green
○
•
Normal Operation
☆
•
Configuration setting not established or not
complete, test run required
Orange
○
•
An error that cannot be recovered
☆
•
An error that can be recovered
Green/
Orange
Blink by turn
•
Self-testing
─
×
No power supply confirmed
DeviceNet communication connector
Monitor LEDs
Red
White
No color
Blue
Black
(XSEL-R/S Series)