69
4. MSEL
No.
Error name
Contents and Treatment
E20 I/O Duplication Assignment Error
I/O assignment is duplicated.
Check to see that a number out of the I/O port number (except for -1)
is not set to I/O Parameters No. 2 to 9, a number out of indication is
not input to I/O port start number, or a number out of indication is not
input to I/O Parameters No. 14 to 17.
[Refer to MSEL Instruction Manual.]
Check the number of the ports that I/O boards are mounted.
E21 I/O Assignment Number Overflow
Error
I/O assignment has exceeded the specified range.
Check to see that a number out of the I/O port number (except for -1)
is not set to I/O Parameters No. 2 to 9, a number out of indication is
not input to I/O port start number, or a number out of indication is not
input to I/O Parameters No. 14 to 17.
[Refer to MSEL Instruction Manual.]
Check the number of the ports that I/O boards are mounted.
E8F Fieldbus logic error
It is a logic error at the Fieldbus initializing.