21
2. XSEL-J/K/P/Q/JX/KX/PX/QX
2.5 Parameter Setting Examples
2.5.1 Setting Example for J/K Types
(1) Setting example when only a DeviceNet board is installed
Assign 32 input points and 16 output points to the DeviceNet board from the first standard I/O port, as you
would for the standard XSEL I/O board (50-pin connector), and do not use any other I/O port.
* In this case, the I/O power connector need not be connected to 24 VDC (K type).
(This example assumes the installed condition shown in Fig. 2-1 and Fig. 2-2 under 2.1.)
XSEL (J type)
Not used.
(Not available on controllers of 1/2-axis specifications.) Input port Nos. 000 to 031
Output port Nos. 300 to 315
Input port Nos. 000 to 031
Output port Nos. 300 to 315
Not used.