125
9.
ASEL, PSEL
and SSEL
73
(2) Using in the positioner mode
Regardless of the settings of I/O parameter Nos. 1, 16 and 17, physical input ports are assigned from No.
0, while physical output ports are assigned from No. 300.
Use input port Nos. 0 to 23 and output port Nos. 300 to 307 according to the I/O port tables for respective
controllers provided on the pages that follow.
I/O parameter Nos. 14 and 15 are both set to “24.”
(Note) I/O parameter Nos. 14 and 15 should be set to the same value corresponding to either the number
of input ports or output ports whichever is greater.