29
2. XSEL-J/K/P/Q/JX/KX/PX/QX
No.
Parameter name
Default value
(reference)
Input
range
Setting
Remarks
121
C80000H
0H ~
FFFFFFFFH
Optional
Network attribute 2
Bits 0 to 11:
"PC/TP Reconnection Latency at Software
Reset" added time (sec) when fieldbus in use
* Valid Values from 0 to 500 (sec)
(XSEL-P/Q: Main application of Ver.1.28 or later
XSEL-PX/QX: Main application of Ver.0.60 or later)
122
1CH
0H ~
FFFFFFFFH
Optional
Network attribute 3
Bits 16 to 27:
Value of Link Timeout at initializing of the
Fieldbus (100ms)
(XSEL-P/Q: Main application of Ver.1.28 or later
XSEL-PX/QX: Main application of Ver.0.60 or later)
(Example) The initial value C80000H is bit
16 to 27= C8H = 200 (in 100ms unit)
200 × 100ms = 20sec
It waits for communication to be
established for 20sec at the
maximum from the startup.