Patients with implanted electronic devices (eg pacemakers) should not be subject to tecar
therapy without the consent of the physician.
-
Avoid use in areas having ongoing inflammatory processes.
USE
-
The operator must pay attention to the necessity of a periodic maintenance (every 2
years) of the probes/applicators. I.A.C.E.R. Srl authorised personnel should carry out such
operations.
-
It is absolutely forbidden to cover the ventilation slots: such an action may not allow the
machine to work in safe conditions. In case of non-compliance with this indication,
I.A.C.E.R. Srl will not be responsible for any accidents.
-
It is absolutely forbidden to cover the ventilation slots: such an action may not allow the
machine to work in safe conditions. In case of non-compliance with this indication,
I.A.C.E.R. Srl will not be responsible for any accidents.
-
It’s important to pay the attention of the operator to the necessity to verify the
correctness of the electric installation of device before activating the supply switch.
-
Before starting the treatment, the operator must make sure to remove all metal objects
from the patient body, in order to avoid the triggering of dangerous radio-frequency
coupling phenomena.
-
Tecar therapy treatments must be provided, under the strict control of the operator, only
to "conscious" patients able to interact with the operator in the face of electrical stress
transmitted from the machine.
-
The premature termination of a therapy session should be done using the “Stop” button: Do
not remove the plug from the 230V wall, do not unplug the power cord or operate the
bipolar ON/OFF switch.
-
Once you start the delivery of a program, the buttons on the toolbar are disabled and the
only allowed operation is to stop dispensing by pressing the PAUSE button.
-
It is advisable to suspend the therapeutic treatment if it were to appear some
disturbances during its emission.
-
It’s strongly advised not to hold the device on in state of start without using the probe, it
could overheat.
-
If the button OK is pressed to confirm the software updating before having onnected the
USB-port to the source containing the software updating, the device goes out from the
main program and enters in the updating routine waiting for the USB connection. A screen
indicates the missed connection. If the support to connect to carry out the updating is not
available, it is necessary to switch off the device and turn it on again through the general
switch to restart the device with the available software.
MAINTENANCE
-
For safety reasons before carrying out any maintenance or cleaning the unit,
YOU MUST
turn off the equipment with the power switch at the back and unplug the socket
connected to the mains.
-
Before every treatment, it is recommended to clean with caution all of the accessories
and the parts of the equipment that have been to contact with the patient.
-
The operator must pay attention to the necessity of a periodic maintenance of the
probes/applicators. Authorized personnel should carry out such operations.
-
The cleaning and disinfection must be done systematically before the therapeutic
treatment which subject the patient.
-
Non spruzzare, ne’ versare liquidi sul contenitore esterno dell’ apparecchio, sulle feritoie
di aerazione, in corrispondenza del display LCD o sulla grata della ventola. The use of
these substances, with the improper use of accessories, irreparably damages the
equipment and the warranty will lapse.
-
Verificare spesso l’integrità del cavo elettrico di alimentazione e dei cavi di collegamento
degli applicatori/accessori applicati al paziente: questi non devono risultare danneggiati,
né logori.
-
It is advised that personnel with technical preparation substitute the fuses, to perform the
operation in safety conditions.
-
Do not open the device: inside there are high voltages that may be hazardous.
-
Only personnel authorized by the manufacturer may access the internal components. For
repairs and further information please contact the fabricant or its authorized service
centers.
WORKING PROBLEMS
−
Do NOT OPEN the unity, as HIGH VOLTAGE ELECTRICITY is present and may prove VERY
DANGEROUS.
I
I
N
N
T
T
R
R
O
O
D
D
U
U
C
C
T
T
I
I
O
O
N
N
T
T
O
O
T
T
H
H
E
E
T
T
E
E
C
C
N
N
O
O
L
L
O
O
G
G
Y
Y
The system of endothermic therapy is a therapeutic method of recent introduction in
physical therapy, that allows to stimulate from the inside the biological structures and
the natural trials mended you and anti-inflammatory through the application of
energy, exploiting a form of interaction energy electromagnetic-tissue that it makes
reference to the physical principle of the condenser.
Device constituted by 2 leaned out elements (called arms) and separated by an
insulating material, connected to an electric generator that a difference of potential
(d.d.p.) creates among the 2 plates. This means that the electric positions are
attracted and are rejected going itself to assemble in proximity of the 2 elements. In
this way an increase of the density of positive position is had in a plate and negative
in the other.
Wanting to move this physical principle to biological field we will have a condenser
constituted by an isolated metallic armor, that is the probe or mobile electrode used
by the operator to treat the part interested by the pathology, while the other armor is
constituted by the biological tissue by to treat, that behaves as a conductor of second
kind.
The mobile electrode is connected to an electric (the body of the car) generator, that
the creates d.d.p., to which and also connected the plate of return, fixed, that is