The  equipment  has  been  designed  and  manufactured  using  highly  advanced 
technology and first class components for reliable and efficient performance.  

However,  should  you  meet  with  any  operational  problems,  we  recommended  that 
you  consult  the  following  guide  before  contacting  any  of  our  authorized  service 
centers. 

If  any  of  the  following  situations  occur,  disconnect  the  machine  and  contact 
authorized service centers: 

 

the  cable  set  or  rear  supply  panel  show  signs  of  wear  and  tear  or  are 
damaged;  

 

the liquid has entered the equipment 

 

the equipment has been exposed to rain.  

E

E

L

L

E

E

C

C

T

T

R

R

O

O

M

M

A

A

G

G

N

N

E

E

T

T

I

I

C

C

 

 

I

I

N

N

T

T

E

E

R

R

F

F

E

E

N

N

C

C

E

E

S

S

 

 

The  I-TECH.AR  equipment  has  been  designed  and  manufactured  according  to  the 
ELECTROMAGNETIC  COMPATIBILITY  DIRECTIVE  2004/108/CE  with  the  aim  of 
providing  adequate  protection  from  harmful  interference  when  installed  in  homes 
and health establishments. 

 All  required  measurements  and  tests  have  been  carried  out  in  I.A.C.E.R.Srl   internal 
Testing, Measurement and Inspection laboratory (LPMC), in addition to other external 
specialised  institutes.  The  customer,  upon  prior  request,  may  view  the  reports 
relative to EMC measures within the company. 

The I-TECH.AR equipment does not generate significant radio frequency energy and is 
adequately immune to radiated electromagnetic fields. 
Therefore  it  does  not  detrimentally  interfere  with  radio-electric  communications, 
electro-medical  equipment  for  monitoring,  diagnosis,  therapy  and  surgery,  office 
electronic  devices  such  as  computers,  printers,  photocopiers,  fax  machines,  etc.  or 
any  electric  or  electronic  equipment  used  in  these  environments,  as  long  as  said 
equipment complies with the ELECTROMAGNETIC COMPATIBILITY directive . 

In  any  case,  in  order  to  avoid  any  interference  problems,  we  recommend  that  you 
operate  the  therapy  equipment  far  enough  away  from  critical  equipment  for 
monitoring vital patient functions, and that you be careful when applying therapy to 
patients with pacemakers .  

T

T

R

R

O

O

U

U

B

B

L

L

E

E

S

S

H

H

O

O

O

O

T

T

I

I

N

N

G

G

 

 

C

C

H

H

A

A

R

R

T

T

 

 

 

 

 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION  

Neither the lights 

nor the LCD 

display on the 

front panel turn 

on: the unit does 

not work. 

Spina di rete non inserita 

correttamente nella presa di 

corrente. 

Verificare il funzionamento 

della presa di corrente. 

Cavo di rete non correttamente 

inserito nel connettore 

dell'apparecchio. 

Inserire correttamente la spina 

ed il cavo nel connettore 

dell'apparecchio. 

Output cables damaged and/or 

or wrongly connected 

 

Replace power cable. 

Power switch off 

Turn power switch on. 

Neither the lights 

nor the LCD 

display on the 

front panel turn 

on: the unit does 

not work. 

Fuse or fuses damaged or blown. 

Replace missing, faulty or blown 

fuse(s). 

Control electronic circuit failure 

Contact I.A.C.E.R. Srl service 

centre. 

Neither the lights 

nor the LCD 

display on the 

front panel turn 

on. 

Faulty components on the 

electronic control card. 

Contact I.A.C.E.R. Srl service 

centre. 

Some controls on 

the front control 

panel do not work 

properly. 

Faulty keys or buttons. 

Contact I.A.C.E.R. Srl service 

centre.  

Control electronic circuit failure. 

The device does 

not emit the 

therapy. 

Faulty connections in circuit 

output applied by operator 

Carefully check the correctness 

and integrity of the output 

connections. 

Handle/applicator cable cut or 

improperly connected 

Replace faulty 

handle/applicator showing signs 

Содержание I-TECH.AR

Страница 1: ...MNPG112 Rev 2 17 05 2013 USER MANUAL...

Страница 2: ...S UP 7 ACCESSORIES 8 CONNECTIONS 8 DEVICE DESCRIPTION 9 HOW TO USE OF THE DEVICE 11 BEST USE 11 SETTINGS 11 VARIOUS 12 LANGUAGE 13 DEFAULT 13 FREE PROCEDURE 13 LOADING PROGRAMS 14 CREATE PROGRAMS 14 M...

Страница 3: ...ntil the decommissioning of equipment The operating instructions must be available for consultation in the vicinity of the machine and properly stored This manual reflects the state of the art at the...

Страница 4: ...nsider hygienic Italian law T U S 81 2008 on safety in the workplace will not be accepted 3 disassemble accessories and any mechanical supports 4 use original box and packing materials 5 enclose Servi...

Страница 5: ...s aggressive solutions or flammable liquids to clean the external parts of the unit and accessories Using these substances or misusing the accessories will cause the immediate voiding of all warranty...

Страница 6: ...unplug the socket connected to the mains Before every treatment it is recommended to clean with caution all of the accessories and the parts of the equipment that have been to contact with the patien...

Страница 7: ...pplying charges to the same armor This establishes a real current in accumulation phase goes from the generator to the condenser As the capacitor builds up charge the flow is reduced to zero when the...

Страница 8: ...urn plate placed at the popliteal groove Coxarthrosis treatment with resistive electrode positioned on the coxofemoral joint In right or left side decubitus return plate positioned on the inside side...

Страница 9: ...n 1 capacitive probe n 1 kit capacitive electrodes diameters 30mm 50 mm and 70mm n 1 bottle of conductive cream 1000ml n 1 steel plate 1 smart card Check the contents of the package and should any of...

Страница 10: ...for problems or difficulty installation CONNECTIONS The power entry module can be found on the back of the unit and consists of a three pole socket for the cable set an extractible fuse box with two f...

Страница 11: ...I A C E R Srl 9 D DE EV VI IC CE E D DE ES SC CR RI IP PT TI IO ON N Programming panel Color graphic LCD display Rear panel Connector for probes Encoder control knob Connector for plate...

Страница 12: ...ive and resistive probes Capacitive electrodes Resistive electrodes Ground connection Integrated power module Ventola di aerazione Connector for STEEL PLATE Connectors for PROBES Audio connector not u...

Страница 13: ...alised application BEST USE After having installed and correctly positioned the machine as per the instructions described in the previous sections and connecting the applicator correctly plug the mach...

Страница 14: ...ormatted You can also use the FORMAT SMART CARD function to delete it completely If you do this it can be used on a different unit Select one of the memory supports to format turning to the right the...

Страница 15: ...o the handle according to its diameter Per modificare tali parametri procedere come segue 1 turn the encoder knob to select the parameter 2 press the knob to highlight the parameter 3 rotate the knob...

Страница 16: ...TART button Before initiation of therapy however you can modify any parameter as discussed in section DEFAULT SETTINGS and FREE PROCEDURE but the program can neither be stored nor renamed C CR RE EA A...

Страница 17: ...denatured alcohol Store with care the probes at the conclusion of every treatment Contact authorised dealers for information regarding original spare parts or components Do not spray or pour liquid on...

Страница 18: ...ocopiers fax machines etc or any electric or electronic equipment used in these environments as long as said equipment complies with the ELECTROMAGNETIC COMPATIBILITY directive In any case in order to...

Страница 19: ...3 15 A T 5 x 20 mm 115 Vac 6 3 A T 5 x 20 mm Peak power 200 Wpk max Peak voltage Capacitive use 300 V max Resistive use 105 V max Probes supplied Resistive probe Capacitive probe Emission Frequency of...

Страница 20: ...oduct shall not be disposed of as domestic waste The user must dispose of scrap equipment by taking it to a recognised centre of recycling of electrical and electronic equipment Appendix B LABELS Symb...

Страница 21: ...min res 15 Cervicalgy x Medium livel 50 70 10 15 Cervical brachialgia x Medium livel 70 10 15 Artropatie da malattie autoimmuni x Medium livel I 12 20 Epicondylitis x Medium livel 50 12 15 Gonarthros...

Страница 22: ...ectrostatic discharge ESD IEC 61000 4 2 6kV contact 6kV contact Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30...

Страница 23: ...th accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ME EQ...

Страница 24: ...nd warehouse 30030 MARTELLAGO VE Via S Pertini 24 A Tel 0039 041 5401356 Fax 0039 041 5402684 Cod Fisc P IVA IT 00185480274 R E A VE N 120250 M VE001767 e mail iacer iacer it Internet www itechmedical...

Отзывы: