I.A.C.E.R. Srl
13
Pressing the EXIT button to cancel the format operation of the selected memory
support and returns to the screen in fig.4. Pressing again the EXIT button to return to
the screen in fig.2.
LANGUAGE
To choice the language in which you wish to have all the commands and messages,
rotate the encoder knob then press this knob at the LANGUAGE menu (see fig.4).
To choose the desired language, rotate the encoder knob until to reach the
correspondent language, then push this knob to confirm the choice.
Finally, press the SAVE button for to train the device to work with the selected
language. Otherwise, press the EXIT button to cancel the operation. In both cases, it
returns to the screen in fig.4.
Pressing the EXIT button to return to the screen in fig.2.
After a short wait for the loading of the new dictionary, you will see the menu with
the new language.To change the language back, you can repeat this procedure at any
time.
DEFAULT
Allows to set the parameters of a standard therapy, most commonly used, that can be
immediately used with the FREE PROCEDURE function.
Press the encoder knob at the DEFAULT menu (see Figure 4). By default, it shows the
MODE parameter.
By turning the encoder knob you can choose the emission mode, as follows:
SEQUENCE (default setting), CAPACITIVE and RESISTIVE.
If you select the CAPACITIVE or RESISTIVE mode the corresponding handle is
automatically disabled, while in the SEQUENCE mode are both active.
The parameters that can be modified are the time of the treatment and the type of
electrode to be applied to the handle, according to its diameter.
Per modificare tali parametri procedere come segue:
1.
turn the encoder knob to select the parameter,
2.
press the knob to highlight the parameter,
3.
rotate the knob to change the parameter value,
4.
press the knob once more to exit the changing procedure.
To save the combination of values selected press the SAVE button, or press the EXIT
button to cancel the operation. In both cases you return to the screen in fig.4.
Press once again the EXIT button to return to the screen in fig.2.
F
F
R
R
E
E
E
E
P
P
R
R
O
O
C
C
E
E
D
D
U
U
R
R
E
E
Allows you to create customized programs that can be used immediately stored by
DEFAUL function.
Pressing the FREE PROCEDURE taste (fig.2), appears the screen of the fig.8.
Fig.8
Before starting treatment, you can change the treatment mode and headpieces
parameters. Select them rotating the encoder knob and then pressing it on the
selected parameter, as explained in section DEFAULT in SETTINGS menu.
To exit the editing routine press once more the encoder knob. However, the modified
program cannot be saved.
To start the treatment press the START button: the countdown initiate and the
hourglass moves to indicate the flowing time.
After pressing the START button you can change the percentage of power (see fig.9)
emitted by rotating the encoder knob.
Pressing the STOP button pauses the emission and the screen shows as Figure 10.
Pressing the START button the emission resumes from where it left off and continues
until the timer expires. At the end the system alerts the operator via a message on
the screen that the treatment is over and you return to the screen in fig.8.
Start
Exit
Time 00:00
Time 15min
Modality:sequence
Time 15min
Probe 30min
Probe 30min
DEFAULT
Capacitive
Resistive