background image

 

 

I.A.C.E.R. Srl 

1

 

 

INFORMATION ON THE MANUAL 

This manual is addressed to: 

- user of the machine; 

- owner; 

- responsible; 

-people in charge of moving; 

- installers; 

- users; 

- people in charge of maintenance.  

This  document  provides  valuable  information  regarding  the  installation,  set  up  and 
use of  I-TECH.AR.  

It  is  a  useful  and  essential  reference  guide  for  the  user:  read  the  contents  of  the 
manual carefully before installing the equipment and keep it on hand at all times for 
future reference.  

It  is  of  vital  importance  that  you  strictly  adhere  to  the  recommendations  contained 
within  the  manual  in  order  to  avoid  malfunction,  which  may  cause  damage  to  the 
equipment and consequent annulment of the validity of the warranty.  

Furthermore,  in  order  to  obtain  the  highly  efficient  technical  service  available  from 
the manufacturer, it is essential that any handling of the equipment be in accordance 
with the instructions provided.  

The limits of this manual are: 

- the user manual cannot replace proper experience; 

- the instruction manual, for particularly difficult operations, can only be a reminder 
of the main operations. 

The  manual  is  to  be  considered  part  of  the  equipment  and  must  be  preserved  for 
future reference until the decommissioning of equipment. The operating instructions 
must be available for consultation in the vicinity of the machine and properly stored.  

This manual reflects the state of the art at the time of sale and cannot be considered 
inadequate because later updated based on new information. The manufacturer has 
the  right  to  update  products  and  manuals  without  necessarily  updating  preceding 

products  or  manuals.  The  company  will  not  assume  any  responsibility  for  any  major 
cases:  

- improper use of the machine; 

- use against to specific national regulations; 

- incorrect installation; 

- defects in power; 

- serious shortcomings in maintenance; 

- changes and unauthorized interventions; 

- use of parts or materials not specific to the model; 

- total or partial non-observance of the instructions; 

- exceptional events.  

Please contact the manufacturer to get further information. 

N.B

. The Therapy Application Manual is available upon request. 

WRITING CONVENTIONS  

Certain  sections  of  the  manual  have  been  underlined  in  order  to  highlight  their 
importance. 

NOTE 

These contain important information and useful tips for operating the equipment. 

CAUTIONS  

The CAUTION message appears before operations, which, if not correctly performed, 
may cause damage to the machine and/or its accessories.  

! WARNING !  

This signals operations or situations, which, if unknown to the operator, or incorrectly 
carried out, may harm the operator.  
 

 

Содержание I-TECH.AR

Страница 1: ...MNPG112 Rev 2 17 05 2013 USER MANUAL...

Страница 2: ...S UP 7 ACCESSORIES 8 CONNECTIONS 8 DEVICE DESCRIPTION 9 HOW TO USE OF THE DEVICE 11 BEST USE 11 SETTINGS 11 VARIOUS 12 LANGUAGE 13 DEFAULT 13 FREE PROCEDURE 13 LOADING PROGRAMS 14 CREATE PROGRAMS 14 M...

Страница 3: ...ntil the decommissioning of equipment The operating instructions must be available for consultation in the vicinity of the machine and properly stored This manual reflects the state of the art at the...

Страница 4: ...nsider hygienic Italian law T U S 81 2008 on safety in the workplace will not be accepted 3 disassemble accessories and any mechanical supports 4 use original box and packing materials 5 enclose Servi...

Страница 5: ...s aggressive solutions or flammable liquids to clean the external parts of the unit and accessories Using these substances or misusing the accessories will cause the immediate voiding of all warranty...

Страница 6: ...unplug the socket connected to the mains Before every treatment it is recommended to clean with caution all of the accessories and the parts of the equipment that have been to contact with the patien...

Страница 7: ...pplying charges to the same armor This establishes a real current in accumulation phase goes from the generator to the condenser As the capacitor builds up charge the flow is reduced to zero when the...

Страница 8: ...urn plate placed at the popliteal groove Coxarthrosis treatment with resistive electrode positioned on the coxofemoral joint In right or left side decubitus return plate positioned on the inside side...

Страница 9: ...n 1 capacitive probe n 1 kit capacitive electrodes diameters 30mm 50 mm and 70mm n 1 bottle of conductive cream 1000ml n 1 steel plate 1 smart card Check the contents of the package and should any of...

Страница 10: ...for problems or difficulty installation CONNECTIONS The power entry module can be found on the back of the unit and consists of a three pole socket for the cable set an extractible fuse box with two f...

Страница 11: ...I A C E R Srl 9 D DE EV VI IC CE E D DE ES SC CR RI IP PT TI IO ON N Programming panel Color graphic LCD display Rear panel Connector for probes Encoder control knob Connector for plate...

Страница 12: ...ive and resistive probes Capacitive electrodes Resistive electrodes Ground connection Integrated power module Ventola di aerazione Connector for STEEL PLATE Connectors for PROBES Audio connector not u...

Страница 13: ...alised application BEST USE After having installed and correctly positioned the machine as per the instructions described in the previous sections and connecting the applicator correctly plug the mach...

Страница 14: ...ormatted You can also use the FORMAT SMART CARD function to delete it completely If you do this it can be used on a different unit Select one of the memory supports to format turning to the right the...

Страница 15: ...o the handle according to its diameter Per modificare tali parametri procedere come segue 1 turn the encoder knob to select the parameter 2 press the knob to highlight the parameter 3 rotate the knob...

Страница 16: ...TART button Before initiation of therapy however you can modify any parameter as discussed in section DEFAULT SETTINGS and FREE PROCEDURE but the program can neither be stored nor renamed C CR RE EA A...

Страница 17: ...denatured alcohol Store with care the probes at the conclusion of every treatment Contact authorised dealers for information regarding original spare parts or components Do not spray or pour liquid on...

Страница 18: ...ocopiers fax machines etc or any electric or electronic equipment used in these environments as long as said equipment complies with the ELECTROMAGNETIC COMPATIBILITY directive In any case in order to...

Страница 19: ...3 15 A T 5 x 20 mm 115 Vac 6 3 A T 5 x 20 mm Peak power 200 Wpk max Peak voltage Capacitive use 300 V max Resistive use 105 V max Probes supplied Resistive probe Capacitive probe Emission Frequency of...

Страница 20: ...oduct shall not be disposed of as domestic waste The user must dispose of scrap equipment by taking it to a recognised centre of recycling of electrical and electronic equipment Appendix B LABELS Symb...

Страница 21: ...min res 15 Cervicalgy x Medium livel 50 70 10 15 Cervical brachialgia x Medium livel 70 10 15 Artropatie da malattie autoimmuni x Medium livel I 12 20 Epicondylitis x Medium livel 50 12 15 Gonarthros...

Страница 22: ...ectrostatic discharge ESD IEC 61000 4 2 6kV contact 6kV contact Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30...

Страница 23: ...th accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the ME EQ...

Страница 24: ...nd warehouse 30030 MARTELLAGO VE Via S Pertini 24 A Tel 0039 041 5401356 Fax 0039 041 5402684 Cod Fisc P IVA IT 00185480274 R E A VE N 120250 M VE001767 e mail iacer iacer it Internet www itechmedical...

Отзывы: