Powermax125
Service Manual 808070
129
8 – Troubleshooting and System Tests
Figure 17
Fault codes beginning with zero (0-
nn
-
n
) are not recorded in the fault log.
To move the field selector (*) between fields, press the current/gas mode selector. The asterisk indicates the selected
field. You can alter the I, C, B, P, and G fields by turning the adjustment knob.
To toggle between (I) Current set/read and (P) Pressure set/read, press the automatic/manual mode selector. The LED is
illuminated when the Pressure set/read field is selected.
To exit the service screen, simultaneously press the automatic/manual and current/gas mode selectors. The operator
screen displays.
Designator
Description
I
Current set/read
C
LCD contrast
B
LCD brightness (percent)
P
Pressure set/read
G
Gas test enable (1)/disable (0)
VL
Incoming AC line voltage
TI
Inverter module temperature (°C)
VB
DC bus voltage
AH
Arc hours
F
Live 4-digit fault code for diagnosing system errors
T
Torch identifier (amperage/hand (H) or machine (M)/lead length in feet)
S
Control/DSP board software versions
(callouts 1 – 6)
Fault log of recent fault codes recorded by the system (0-00-0) and the
last 3 digits of the arc hour count when the fault occurred (000). Callout 1
is the most recent fault code.
1
3
5
2
4
6