272
Powermax125
Service Manual 808070
10 – Torch Component Replacement
Install the handle
1.
Make sure that the pilot terminal screw is tightened to 17.3 kg-cm (15 inch-pounds).
2.
Lay the right side of the handle on a flat surface with the inside facing up.
If replacing the handles, apply the “H” label to the right side of the torch handle and the
Duramax label to the left side of the torch handle.
3.
Press the cap-sensor switch into its post hole and onto its mounting posts. (See
Figure 126
4.
Route the cap-sensor wires as shown in
. Position the wires below the slot for the gas hose fitting’s
flange.
5.
Press the start switch onto the 2 mounting posts and position the wires below the slot for the gas hose fitting’s
flange. (See
Содержание Powermax 125