22
Powermax125
Service Manual 808070
1 – Specifications
Hypertherm power supply ratings
Rated open-circuit voltage (U
0
)
480/600 V CSA
400 V CE
380 V CCC
320 VDC
305 VDC
290 VDC
Output characteristic
1
Drooping
Rated output current (I
2
)
30 – 125 A
Rated output voltage (U
2
)
175 VDC
Duty cycle at 40° C (104° F)
480/600 V CSA
400 V CE
380 V CCC
100% at 125 A, 480/600 V, 3-PH
100% at 125 A, 400 V, 3-PH
100% at 125 A, 380 V, 3-PH
Operating temperature
-10° to 40° C (14° to 104° F)
Storage temperature
-25° to 55° C (-13° to 131° F)
Power factor
0.94
R
sce
– Short Circuit Ratio (CE models
only)
U
1
– Volts AC rms, 3-PH
R
sce
400 V CE
250
EMC emissions classification
CISPR 11 (CE models only)
2
Class A
Input voltage (U
1
)/ Input current (I
1
) at
rated output (U
2 MAX
I
2 MAX
)
480/600 V CSA 480/600 V, 3-PH, 50/60 Hz, 31/24 A
400 V CE
3,4
400 V, 3-PH, 50/60 Hz, 36 A
380 V CC 380 V, 3-PH, 50/60 Hz, 38 A
Gas type
Air
Nitrogen
Gas quality
Clean, dry, oil-free per ISO 8573-1
Class 1.2.2
99.95% pure
Recommended gas inlet flow
rate/pressure
Cutting: 260 slpm (550 scfh, 9.2 scfm) at:
• 5.9 bar (85 psi) for 7.6 m (25 foot) and 15 m (50 foot) torches
• 6.6 bar (95 psi) for 23 m (75 foot) torches
Gouging: 212 slpm (450 scfh, 7.5 scfm) at 4.1 bar (60 psi)
1
Defined as a plot of output voltage versus output current.
2
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations due to
conducted or radiated disturbances.
3
This product meets the technical requirements of IEC 61000-3-3 and is not subject to conditional connection.
4
Equipment complies with IEC 61000-3-12 provided that the short-circuit power S
sc
is greater than or equal to 5363 KVA at the
interface point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with
a short-circuit power S
sc
greater than or equal to 5363 KVA.
Содержание Powermax 125
Страница 1: ...Powermax125 Plasma Arc Cutting System Service Manual 808070 Revision 1 English ...
Страница 3: ...Powermax125 Service Manual 808070 Revision 1 English April 2014 Hypertherm Inc Hanover NH 03755 USA ...
Страница 6: ......
Страница 56: ...56 Powermax125 Service Manual 808070 4 Hand Torch Setup ...