Power connection for the Powermax125
Powermax125 3-phase systems are available in the following fixed-voltage configurations:
480 V CSA
600 V CSA
400 V CE
380 V CCC
To maintain CE certification, install power cord kit 228886.
The Hypertherm rated output is 30 – 125 A, 175 VDC.
Table 4 – 480 V CSA
Table 5 – 600 V CSA
Table 6 – 400 V CE
Input voltage (V)
480
Input current (A) at rated output (21.9 kW)
31
Input current (A) at arc stretch
50
Fuse, slow-blow (A)
50
Voltage tolerance
+20% / -15%
Input voltage (V)
600
Input current (A) at rated output (21.9 kW)
24
Input current (A) at arc stretch
38
Fuse, slow-blow (A)
40
Voltage tolerance
+10% / -15%
Input voltage (V)
400
Input current (A) at rated output (21.9 kW)
36
Input current (A) at arc stretch
55
Fuse, slow-blow (A)
60
Voltage tolerance
+20% / -15%