background image

USER MANUAL

DT-ENG-DT607-V1  /  201607

• 

Please read this manual carefully to  ensure  safe  and  correct  operation.

• 

 Keep  this manual well  for  future  reference.

RF CARD

RF CARD

RF CARD

RF CARD

RF CARD

RF CARD

DT607A/ID-S4

DT607/ID/FE-S1

DT607/ID/FE-S2

DT607F/ID/FE-S4

DT607/ID/FE-S3

DT607/ID/FE-S4

DT607 Series

2 WIRE SYSTEM

Fisheye door station with proximity access control

Summary of Contents for DT607

Page 1: ...e and correct operation Keep this manual well for future reference RF CARD RF CARD RF CARD RF CARD RF CARD RF CARD DT607A ID S4 DT607 ID FE S1 DT607 ID FE S2 DT607F ID FE S4 DT607 ID FE S3 DT607 ID FE...

Page 2: ...de 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Ima...

Page 3: ...8 7 6 5 12 11 12 13 13 2 2 Surface mounted Flush mounted 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rainy cove...

Page 4: ...and the distance between the top of main unit and rain cover should be not less than 3mm 3 Install the name plate 4 Attach the front panel to the main unit 5 Use the special screwdriver and the screw...

Page 5: ...ocks L1 L2 Connect to the bus line no polarity PL External lock power input connect to the power positive power S Lock power output S Lock power output connect to the power input of locks only when us...

Page 6: ...res the monitor with fisheye function to support The angle view is 1700 visitors in this angle view can be seen clearly and can be zoomed to see individuals up close via indoor monitor with fisheye fu...

Page 7: ...Order Setting items Setting range Default value 1 Setting door station address 0 3 0 2 Setting door station calling mode Standard Group calling mode Standard calling mode 3 Setting camera resolution...

Page 8: ...FF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 1st door station ID 1 2nd d...

Page 9: ...address 02 by default Call buttonC call the monitor with address 03 by default Call buttonD call the monitor with address 04 by default Call buttonA Call all monitors in group address from 00 15 one...

Page 10: ...ode press KEY_SET button three times UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Press KEY_1 button to set the unlock mode to Normally opened UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep...

Page 11: ...ion mode to Normally on UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press KEY_3 button again to set the nameplate illumina tion mode to Normally off UNLOCK Indicator ON TALK Indicator OFF...

Page 12: ...Auto Press KEY_4 UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep In standby mode press KEY_SET button four times UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Press KEY_1 button to set the...

Page 13: ...swering the call image switching reminder is not effective Zoom mode When answering the call the image will be displayed on full screen for 5 sec onds then switch to Zoom image to remind to enter talk...

Page 14: ...Hz Authorizing master cards By default there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE but you should know that the master card can be authorized by users at any time That mea...

Page 15: ...l exit out setting mode automatically If current access is controlled by door station next access switching setting is controlled by DT ACC UNLOCK Indicator Blink two times TALK Indicator OFF Buzzer B...

Page 16: ...equence UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Show the master card of MASTER CARD DELETE again to exit UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Show the master card o...

Page 17: ...Exit Button EB 5 The Unlock Mode must be set to 0 by default 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jum...

Page 18: ...on 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches RF CARD PC6A AC 100 240VAC 100 240VAC DBC4A1 A B C D OFF ON Impedance switch BUS IM BUS DS PC6A AC ID 0 1st door station ID 1 2nd door station ID 2 3rd door st...

Page 19: ...fer to Page 9 Distributor is unnecessary in full audio system and IN OUT mode is recom mended For the last monitor connected to the system DIP6 should set to ON ID 0 Code 1 DIP6 off Optional functiona...

Page 20: ...stributor for the extension WIRING DBC4A1 A B C D RLC DBC4A1 OFF ON Impedance switch BUS IM BUS DS Code 1 DIP6 on Code 2 DIP6 on Code 3 DIP6 on Code 4 DIP6 on ID 0 RF CARD PC6A AC 100 240VAC Optional...

Page 21: ...acture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional APPENDIX Power supply DC 24V Power consumption Standby 0 8W Working 3W Ca...

Page 22: ...limited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40...

Page 23: ...23 B A C 2 2 DBC4A1 RF CARD PC6A Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1...

Page 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG DT607 V1...

Reviews: