9 – Power Supply Component Replacement
5.
Route the long cable, small connector first, through the RS-485 mounting hole in the rear panel.
6.
Fasten the RS-485 connector in the mounting hole of the rear panel, with the red wire on top (see
), by
tightening the 2 supplied screws to 11.5 kg-cm (10 inch-pounds).
Figure 54
7.
Route the RS-485 cable next to the 2 existing gray cables, above the solenoid valve and through the cable clip
attached to the center panel.
8.
Push the small connector from the RS-485 cable through the center grommet in the center panel.
Figure 55
Red wire
Cable clip
Solenoid valve
Center grommet
Содержание Powermax 125
Страница 1: ...Powermax125 Plasma Arc Cutting System Service Manual 808070 Revision 1 English ...
Страница 3: ...Powermax125 Service Manual 808070 Revision 1 English April 2014 Hypertherm Inc Hanover NH 03755 USA ...
Страница 6: ......
Страница 56: ...56 Powermax125 Service Manual 808070 4 Hand Torch Setup ...