Page 43
11.4 Pressure
regulator: replace backflow pre-
venter
11.5 Pressure
regulator functional check
11.6 Drain valve functional check
11.7 Functional checks with pressure check
equipment.
Functional checks
for the drain valve and
the outlet backflow pre-
venter
must be carried out with special testing equipment. For this
purpose, contact an installation company.
Figure
Step
Action
1
(1 in fig.)
Close ball cocks on inlet and outlet sides.
2
(2 in fig.)
Depressurise system separator:
Unscrew sealing plug.
3
(3 in fig.)
Remove valve insert according to section 11.3.
4
(4 in fig.)
•
Unscrew cover
•
Remove seal
•
Pull out backflow preventer and replace
•
Reinsert seal and screw on cover
•
Screw on sealing plug and handtighten
5
Reattach valve insert according to section 11.3.
6
Check function: see section 11.5.
.
Step
Action
1
Close ball valve on outlet side.
2
Check pressure on outlet pressure gauge during zero flow:
In case of the outlet pressure slowly rising, either the valve seat or the
valve disc within the pressure regulator may be contaminated or
defective.
Check valve insert and strainer in pressure regulator.
3
Slowly open outlet ball valve.
Step
Action
1
Lower inlet pressure: if drain valve opens (i.e. water drips out) the
drain valve functions properly.
Содержание WL-RO-170
Страница 1: ...Reverse osmosis plants WL ROB 170 WL RO 170 WLROB170 ENx WLROB170 EN Manual...
Страница 21: ...Page 21 5 5 Dimension sheet Fig 3 Front Top view Permeate Connection R3 4...
Страница 22: ...Page 22 Fig 4 Lateral view Fig 5 Front view of securing and fixing plate Concentrate Hose 8 Wastewater drain...
Страница 46: ...Seite 46 This page intentionally left blank...