Page 39
Isolating the system
Pulling out the membrane
Step Action
1
Pull power plug.
2
Cut-off raw water supply.
3
Depressurise reverse osmosis system by opening sample valve in
permeate pipe line.
Step
Action
1
Disconnect
the
pipeline
attached to the
cover of the pressure pipe (permeate out-
let).
Pull back the ring on the bushing and
remove pipe line from bushing.
2
Unscrew and pull off the cap from the
pressure pipe
.
The cap sits very tightly in the pressure pipe
and a suitable tool must be used to pull it
off.
3
Pull out the membrane
.
The membrane sits very tightly in the pres-
sure pipe and a suitable tool must be used
to pull it off.
Содержание WL-RO-170
Страница 1: ...Reverse osmosis plants WL ROB 170 WL RO 170 WLROB170 ENx WLROB170 EN Manual...
Страница 21: ...Page 21 5 5 Dimension sheet Fig 3 Front Top view Permeate Connection R3 4...
Страница 22: ...Page 22 Fig 4 Lateral view Fig 5 Front view of securing and fixing plate Concentrate Hose 8 Wastewater drain...