9.3 Stand-by operation
On reaching the operational pressure required in the system to
be filled, the plant automatically shuts down by means of the
pressure switch (permeate) :
•
the high-pressure pump stops
•
the raw water inlet valve remains open in order to push-out
the concentrate from the membrane
•
the plant goes to stand-by mode with the raw water inlet
valve close and a flashing green LED
9.4 System shut-down
Please note
The plant may only be shut-down for maintenance or for perma-
nent closure. When in production mode, cyclic permeate con-
sumption is mandatory in order for the system not to be prone to
microbial contamination.
When used with active HygroMatik products, permeate con-
sumption is guarantied within a 24 hour time frame minimum.
For switching off the system simply pull out the mains plug from
the power socket.