10.2 Rest fault indication
10.3 Involve HygroMatik service personnel
In case of not succeeding in finding the problem cause, or if
troubleshooting has not resolved the problem, please call Hygro-
Matik GmbH.
LED state
Meaning
Possible cause
troubleshooting
Gre
en and
re
d LED
off
Fault control device
Possible fault cause
•
Control device defective
Tests/measures for troubles-
hooting
•
Is the mains plug inserted
in a power socket?
•
Is the power socket functio-
nal?
illuminate briefly
and simultanously
Self-test
The system runs a self-test and
then enters stand-by mode or
starts production.
Step
Action
Result
1
Pull power plug.
-
2
Check power cable for damage
and re-insert power plug into a po-
wer socket.
The control device runs a self-test:
The green and red LEDs briefly
flash yellow. Following this, the sy-
stem enters stand-by mode or
starts production.